346 research outputs found

    VELOX – A Demonstration Facilility for Lunar Oxygen Extraction in a Laboratory Environment

    Get PDF
    The ultimate goal of a permanent human presence on the Moon is discussed intensively within the global lunar community. Obviously, such an effort poses stringent demands not only on the technology but also on logistics, especially considering the important aspects of masses and volume for materials and replenishments of consumables. On-site propellant production (i.e. liquid oxygen) is one of the main needs and would lead to more efficient return-to-Earth or further exploration missions. Additionally, the supply of breathable air and water for the survival of the crew on the lunar surface is also a major aspect. Thus, large effort is put into the development and research of technologies for in-situ resources utilization (ISRU) to drastically reduce the required supply from Earth and to increase the level of autonomy of a lunar outpost. The major resource on the Moon for such a purpose is regolith, which covers the first meters of the lunar surface and contains about 45% of mineralogically bounded Oxygen in terms of mass. By using adequate processing methods of this material, one could be able to extract valuable minerals and volatiles for further utilization. At DLR Bremen a compact and flexible lab experimenting facility has been developed, built and tested, which shall demonstrate the feasibility of the process by extracting oxygen out of lunar regolith, respectively soil simulants and certain minerals in the laboratory case. For this purpose, important boundary conditions have been investigated such as temperatures during the process, chemical reaction characteristics and material properties for the buildup of the facility, which shall be analyzed within this paper. Since it is one of the most elaborated chemical processes regarding ISRU and has comparably low temperature and energy constraints it has been primarily concentrated on the Hydrogen-reduction process which reduces the iron oxide component of Ilmenite (FeTiO3) within the lunar regolith. Based on the obtained results, a first line-out of a planned superior test set-up and infrastructure with pre- and post-processing units such as feeding and extraction is also presented, as well as an analysis of reaction products with common methods. This paper will present the first results of DLR efforts regarding these topics. Finally, important aspects of the future development of the processes and technologies are discussed with special consideration of lunar applicability and with respect to environmental conditions as well as mass and energy constraints

    Parameters of the Effective Singlet-Triplet Model for Band Structure of High-TcT_c Cuprates by Different Approaches

    Full text link
    The present paper covers the problem of parameters determination for High-TcT_c superconductive copper oxides. Different approaches, {\it ab initio} LDA and LDA+U calculations and Generalized Tight-Binding (GTB) method for strongly correlated electron systems, are used to calculate hopping and exchange parameters of the effective singlet-triplet model for CuO2CuO_2-layer. The resulting parameters are in remarkably good agreement with each other and with parameters extracted from experiment. This set of parameters is proposed for proper quantitative description of physics of hole doped High-TcT_c cuprates in the framework of effective models.Comment: PACS 74.72.h; 74.20.z; 74.25.Jb; 31.15.A

    Frenkel and charge transfer excitons in C60

    Full text link
    We have studied the low energy electronic excitations of C60 using momentum dependent electron energy-loss spectroscopy in transmission. The momentum dependent intensity of the gap excitation allows the first direct experimental determination of the energy of the 1Hg excitation and thus also of the total width of the multiplet resulting from the gap transition. In addition, we could elucidate the nature of the following excitations - as either Frenkel or charge transfer excitons.Comment: RevTEX, 3 Figures, to appear in Phys. Rev.

    Theory for Dynamical Short Range Order and Fermi Surface Volume in Strongly Correlated Systems

    Full text link
    Using the fluctuation exchange approximation of the one band Hubbard model, we discuss the origin of the changing Fermi surface volume in underdoped cuprate systems due to the transfer of occupied states from the Fermi surface to its shadow, resulting from the strong dynamical antiferromagnetic short range correlations. The momentum and temperature dependence of the quasi particle scattering rate shows unusual deviations from the conventional Fermi liquid like behavior. Their consequences for the changing Fermi surface volume are discussed. Here, we investigate in detail which scattering processes might be responsible for a violation of the Luttinger theorem. Finally, we discuss the formation of hole pockets near half filling.Comment: 5 pages, Revtex, 4 postscript figure

    Insight into the Assembly Properties and Functional Organisation of the Magnetotactic Bacterial Actin-like Homolog, MamK

    Get PDF
    Magnetotactic bacteria (MTB) synthesize magnetosomes, which are intracellular vesicles comprising a magnetic particle. A series of magnetosomes arrange themselves in chains to form a magnetic dipole that enables the cell to orient itself along the Earth’s magnetic field. MamK, an actin-like homolog of MreB has been identified as a central component in this organisation. Gene deletion, fluorescence microscopy and in vitro studies have yielded mechanistic differences in the filament assembly of MamK with other bacterial cytoskeletal proteins within the cell. With little or no information on the structural and behavioural characteristics of MamK outside the cell, the mamK gene from Magnetospirillium gryphiswaldense was cloned and expressed to better understand the differences in the cytoskeletal properties with its bacterial homologues MreB and acitin. Despite the low sequence identity shared between MamK and MreB (22%) and actin (18%), the behaviour of MamK monitored by light scattering broadly mirrored that of its bacterial cousin MreB primarily in terms of its pH, salt, divalent metal-ion and temperature dependency. The broad size variability of MamK filaments revealed by light scattering studies was supported by transmission electron microscopy (TEM) imaging. Filament morphology however, indicated that MamK conformed to linearly orientated filaments that appeared to be distinctly dissimilar compared to MreB suggesting functional differences between these homologues. The presence of a nucleotide binding domain common to actin-like proteins was demonstrated by its ability to function both as an ATPase and GTPase. Circular dichroism and structural homology modelling showed that MamK adopts a protein fold that is consistent with the ‘classical’ actin family architecture but with notable structural differences within the smaller domains, the active site region and the overall surface electrostatic potential

    Solar magnetism eXplorer (SolmeX)

    Get PDF
    The magnetic field plays a pivotal role in many fields of Astrophysics. This is especially true for the physics of the solar atmosphere. Measuring the magnetic field in the upper solar atmosphere is crucial to understand the nature of the underlying physical processes that drive the violent dynamics of the solar corona—that can also affect life on Earth. SolmeX, a fully equipped solar space observatory for remote-sensing observations, will provide the first comprehensive measurements of the strength and direction of the magnetic field in the upper solar atmosphere. The mission consists of two spacecraft, one carrying the instruments, and another one in formation flight at a distance of about 200 m carrying the occulter to provide an artificial total solar eclipse. This will ensure high-quality coronagraphic observations above the solar limb. SolmeX integrates two spectro-polarimetric coronagraphs for off-limb observations, one in the EUV and one in the IR, and three instruments for observations on the disk. The latter comprises one imaging polarimeter in the EUV for coronal studies, a spectro-polarimeter in the EUV to investigate the low corona, and an imaging spectro-polarimeter in the UV for chromospheric studies. SOHO and other existing missions have investigated the emission of the upper atmosphere in detail (not considering polarization), and as this will be the case also for missions planned for the near future. Therefore it is timely that SolmeX provides the final piece of the observational quest by measuring the magnetic field in the upper atmosphere through polarimetric observations

    Ultrafast 3d spin-echo acquisition improves gadolinium-enhanced mri signal contrast enhancement

    Get PDF
    Long scan times of 3D volumetric MR acquisitions usually necessitate ultrafast in vivo gradient-echo acquisitions, which are intrinsically susceptible to magnetic field inhomogeneities. This is especially problematic for contrast-enhanced (CE)-MRI applications, where non-negligible T 2 & z.ast; effect of contrast agent deteriorates the positive signal contrast and limits the available range of MR acquisition parameters and injection doses. To overcome these shortcomings without degrading temporal resolution, ultrafast spin-echo acquisitions were implemented. Specifically, a multiplicative acceleration factor from multiple spin echoes (??32) and compressed sensing (CS) sampling (??8) allowed highly-accelerated 3D Multiple-Modulation- Multiple-Echo (MMME) acquisition. At the same time, the CE-MRI of kidney with Gd-DOTA showed significantly improved signal enhancement for CS-MMME acquisitions (??7) over that of corresponding FLASH acquisitions (??2). Increased positive contrast enhancement and highly accelerated acquisition of extended volume with reduced RF irradiations will be beneficial for oncological and nephrological applications, in which the accurate in vivo 3D quantification of contrast agent concentration is necessary with high temporal resolution.open0

    Monte Carlo Analysis of Neck Linker Extension in Kinesin Molecular Motors

    Get PDF
    Kinesin stepping is thought to involve both concerted conformational changes and diffusive movement, but the relative roles played by these two processes are not clear. The neck linker docking model is widely accepted in the field, but the remainder of the step – diffusion of the tethered head to the next binding site – is often assumed to occur rapidly with little mechanical resistance. Here, we investigate the effect of tethering by the neck linker on the diffusive movement of the kinesin head, and focus on the predicted behavior of motors with naturally or artificially extended neck linker domains. The kinesin chemomechanical cycle was modeled using a discrete-state Markov chain to describe chemical transitions. Brownian dynamics were used to model the tethered diffusion of the free head, incorporating resistive forces from the neck linker and a position-dependent microtubule binding rate. The Brownian dynamics and chemomechanical cycle were coupled to model processive runs consisting of many 8 nm steps. Three mechanical models of the neck linker were investigated: Constant Stiffness (a simple spring), Increasing Stiffness (analogous to a Worm-Like Chain), and Reflecting (negligible stiffness up to a limiting contour length). Motor velocities and run lengths from simulated paths were compared to experimental results from Kinesin-1 and a mutant containing an extended neck linker domain. When tethered by an increasingly stiff spring, the head is predicted to spend an unrealistically short amount of time within the binding zone, and extending the neck is predicted to increase both the velocity and processivity, contrary to experiments. These results suggest that the Worm-Like Chain is not an adequate model for the flexible neck linker domain. The model can be reconciled with experimental data if the neck linker is either much more compliant or much stiffer than generally assumed, or if weak kinesin-microtubule interactions stabilize the diffusing head near its binding site

    Indications, Postoperative Management, and Long-term Prognosis of Crohn's Disease After Ileocecal Resection: A Multicenter Study Comparing the East and West

    Get PDF
    Background The Crohn's disease (CD) phenotype differs between Asian and Western countries and may affect disease management, including decisions on surgery. This study aimed to compare the indications, postoperative management, and long-term prognosis after ileocecal resection (ICR) in Hong Kong (HK) and the Netherlands (NL). Methods CD patients with primary ICR between 2000 and 2019 were included. The endpoints were endoscopic (Rutgeerts score >= i2b and/or radiologic recurrence), clinical (start or switch of inflammatory bowel disease medication), and surgical recurrences. Cumulative incidences of recurrence were estimated with a Bayesian multivariable proportional hazards model. Results Eighty HK and 822 NL patients were included. The most common indication for ICR was penetrating disease (HK: 32.5%, NL: 22.5%) in HK vs stricturing disease (HK: 32.5%, NL: 48.8%) in the NL (P < .001). Postoperative prophylaxis was prescribed to 65 (81.3%) HK patients (28 [35.0%] aminosalicylates [5-aminosalicylic acid]; 30 [37.5%] immunomodulators; 0 biologicals) vs 388 (47.1%) NL patients (67 [8.2%] 5-aminosalicylic acid; 187 [22.8%] immunomodulators; 69 [8.4%] biologicals; 50 [6.1%] combination therapy) (P < .001). Endoscopic or radiologic evaluation within 18 months was performed in 36.3% HK vs 64.1% NL (P < .001) patients. No differences between both populations were observed for endoscopic (hazard ratio [HR], 0.53; 95% confidence interval [CI], 0.24-1.21), clinical (HR, 0.91; 95% CI, 0.62-1.32), or surgical (HR, 0.61; 95% CI, 0.31-1.13) recurrence risks. Conclusion The main indication for ICR in CD patients is penetrating disease in HK patients and stricturing disease in NL patients. Although considerable pre- and postoperative management differences were observed between the two geographical areas, the long-term prognosis after ICR is similar.Lay Summary This is the first study reporting similar long-term prognoses after ileocecal resection in Crohn's disease in low- and high-incidence countries despite differences in Crohn's disease phenotype at diagnosis, surgical approach, indications, and pre- and postoperative management including prophylactic medication.Cellular mechanisms in basic and clinical gastroenterology and hepatolog

    Sheddable Coatings for Long-Circulating Nanoparticles

    Get PDF
    Nanoparticles, such as liposomes, polymeric micelles, lipoplexes and polyplexes are frequently studied as targeted drug carrier systems. The ability of these particles to circulate in the bloodstream for a prolonged period of time is often a prerequisite for successful targeted delivery. To achieve this, hydrophilic ‘stealth’ polymers, such as poly(ethylene glycol) (PEG), are used as coating materials. Such polymers shield the particle surface and thereby reduce opsonization by blood proteins and uptake by macrophages of the mononuclear phagocyte system. Yet, after localizing in the pathological site, nanoparticles should deliver their contents in an efficient manner to achieve a sufficient therapeutic response. The polymer coating, however, may hinder drug release and target cell interaction and can therefore be an obstacle in the realization of the therapeutic response. Attempts have been made to enhance the therapeutic efficacy of sterically stabilized nanoparticles by means of shedding, i.e. a loss of the coating after arrival at the target site. Such an ‘unmasking’ process may facilitate drug release and/or target cell interaction processes. This review presents an overview of the literature regarding different shedding strategies that have been investigated for the preparation of sterically stabilized nanoparticulates. Detach mechanisms and stimuli that have been used are described
    corecore